This page must be viewed with IE4 or above, and with Active Scripting enabled.
APPLICATION SPECIFIC SWITCHES
SERIES 24 AND SERIES 31 R0TARY SWITCHES
Depth Behind Panel: 2.4" Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown CONTACTS POS. 1 3 1 4 1 7 115-16 1 2 BREAKER CONTROL CLOSE TRIP CIRCUIT BREAKER- Trip Switch CIRCUIT BREAKER- Control Switches CIRCUIT BREAKER-Control Switches Transfers two wires to three coils, with “TEST” and  “OFF” Depth Behind Panel: 2.9" Handle: Round, Knurled Engraving and jumpering as shown CONTACTS POS. 1 8 1 7 1 1 1 1 6 TEMP. METER TEST OFF 1 2 3 BREAKER CONTROL TRIP BREAKER CONTROL CLOSE TRIP Double-pole single-throw contacts normally open Depth Behind Panel: 2.4"   Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown Depth Behind Panel: 2.4" Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown Operate two breakers Depth Behind Panel: 2.4" Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown CONTACTS POS. 1 8 1 3 1 4 1 7 1 11-12 15-16 BREAKER CONTROL CLOSE TRIP Depth Behind Panel: 4.3" Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown CONTACTS POS. 1 2 1 4 1 7 2 3 2 7 115-16 1 1 2 2 2 6 2 BREAKER CONTROL CLOSE TRIP CONTACTS POS. 1 3 1 7 1 1 2 1 6 TEMPERATURE METER- Transfer Switch *Deck #2 MBB  (shorting) contacts Note: Contacts 11-12 & 15-16 connected  internally in normal position Note: Contacts 11-12 & 15-16 connected  internally in normal position Note: Contacts 11-12 & 15-16 connected   internally in normal position CONTACTS POSITIONS 1 2 3 1 2 1 3 1 4 1 5 2 2 2 3 2 4 2 5 1 1 1 1 2 2   * Order # Series 24 = 2432C Series 31 = 3132C Order # Series 24 = 2436D Order # Series 24 = 2438D Order # Series 24 = 2440D Order # Series 24 = 2441D Order # Series 24 = 2442D POWER-FACTOR–Switch SYNCHRONIZING-Switch MOTOR CONTROL-Switch, 3-phase, two  current-transformers, one or two current-coils Depth Behind Panel: 2.4 " Handle: Round, Knurled Engraving and jumpering as shown CONTACTS POS. 1 3 1 5 1 7 1 1 2 1 6 P.F. METER ON OFF Machine-to-bus with interlocks Depth Behind Panel: 2.9" Handle: Oval, Removable Engraving and jumpering as shown CONTACTS POS. 1 3 1 7 2 3 2 7 1 1 2 1 6 2 2 2 6 2 SYNCHROSCOPE ON OFF Split-field motor Depth  Behind Panel: 2.4" Handle: Pistol-Grip, Spring-Return Engraving and jumpering as shown CONTACTS POS. 1 8 1 3 1 4 1 7 1 11-12 15-16 MOTOR CONTROL LOWER RAISE * Contacts 11-12 & 15-16 connected internally in normal position Governor or Rheostat Order # Series 24 = 2422C Series 31 = 3122C Order # Series 24 = 2424E Order # Series 24 = 2427D Series 31 = 3127D